    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498036792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2639595; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02002165482772925,
        0.03268020874784052,
        0.028489651244297125,
        0.00014297610446493354,
        0.00010611457715017919,
        0.000057719198420801505,
        0.02243691402921907,
        0.05457267070266622,
        0.10281539592248053,
        0.10192735195036684,
        0.08711079313303745,
        0.06974567793358376,
        0.048541216040281235,
        0.00999623048232778,
        0.00021756290151975474,
        0.0001120680438407476,
        0.007599439625884166,
        0.2461148930908227,
        0.5677642782320772,
        0.7134458949002224,
        0.6863059219312052,
        0.6073381041223443,
        0.5125921981310793,
        0.4393552498148089,
        0.3704019141667566,
        0.2953321998843937,
        0.22800512153867494,
        0.15275831793847386,
        0.083564697926587,
        0.03161717403342316,
        0.020480033111140154
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498036792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2639595; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02604868996948395,
        0.03964056972154681,
        0.07597166295081884,
        0.11715908496709566,
        0.16241593966980813,
        0.19894107189423627,
        0.25003240055683773,
        0.3433903782708767,
        0.46043838890688404,
        0.5740062357277984,
        0.7074262491026084,
        0.867846781604828,
        0.9757051773822528,
        1,
        0.9675136751127575,
        0.8944855397065906,
        0.7932145969092119,
        0.6617511870424833,
        0.5273667988904515,
        0.39535650323346666,
        0.2863272262095763,
        0.19966082011028827,
        0.1505815165070839,
        0.11062823586723275,
        0.08009098608167162,
        0.05386821667135124,
        0.03929420049345265,
        0.022093997069258672,
        0.010580323920013129,
        0.008755956330696427,
        0.0018636767112270739
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus TG 4 / prf-solomatov-pred-olympus-tg-4-cf7bb3692d5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498036792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2639595; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0628333498131342,
        0.15068231448477476,
        0.3495768504890586,
        0.5821580733161276,
        0.7202260884030246,
        0.7998337236499454,
        0.8552519873560971,
        0.8436168153294631,
        0.7707195816656216,
        0.6443216292728271,
        0.4854739161121308,
        0.3386986164581324,
        0.21569750640650434,
        0.1412586589988237,
        0.11498130507254443,
        0.10284536997669579,
        0.10588468293160773,
        0.10173150679049879,
        0.083104655096318,
        0.060941706163769795,
        0.04565054967397145,
        0.03374707881012173,
        0.015877124050494306,
        0.000035907132338153,
        0.0000041800981128260205,
        0.00004463626048693076,
        0.00002321398105896296,
        0.00005300972325215087,
        0.0000611249519339141,
        0.000015000710610770848,
        0.0006342364756714571
      ],
      "range": 1
    }
  }
]