[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26683265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26683265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012511875889251185,
        0.021439200562599816,
        0.02227350850804802,
        0.0006849905736797952,
        0.000006516153101953602,
        0.01472798924719295,
        0.043059781102500014,
        0.06845544201581029,
        0.10660566838428505,
        0.11063564747417529,
        0.09998832601632521,
        0.08819880175833054,
        0.07193839284660254,
        0.038807089387299494,
        0.0005104385089305975,
        0.00010530976250470097,
        0.037097735228428755,
        0.26201016254944814,
        0.5911439623299473,
        0.7457193488128233,
        0.7194530729279195,
        0.6537543287899737,
        0.5643648181734882,
        0.48980122934730813,
        0.42090711162970496,
        0.34679905176521686,
        0.276491688704512,
        0.19687339611550536,
        0.11734659532857018,
        0.04753710987017518,
        0.03406641203765731
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26683265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26683265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018756914867801972,
        0.0309934147863839,
        0.060422815573731324,
        0.0963338519480281,
        0.13622459620290095,
        0.17580516477275174,
        0.235252132750621,
        0.34118688248983026,
        0.47004199073838976,
        0.5926211054007071,
        0.7258506033650679,
        0.8768413460646589,
        0.9735592702017537,
        1,
        0.9734489013994352,
        0.9081504830836855,
        0.8164220532982003,
        0.6891719960057362,
        0.5480363066513787,
        0.411326462485007,
        0.2960820199477088,
        0.20718538754533974,
        0.1517532056140806,
        0.10647412900932475,
        0.072986495468227,
        0.0472016486738036,
        0.03411570510580321,
        0.017973501368741793,
        0.011720718585225609,
        0.0073747421839119014,
        0.003260639205884287
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 1 / prf-solomatov-pred-olympus-xz-1-ebe35cb5a9a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26683265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26683265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04798328465425802,
        0.11647966618777725,
        0.2741351405084797,
        0.4599960312203173,
        0.5813880722617715,
        0.6625565124807627,
        0.7193723481740334,
        0.7274480465565215,
        0.6861976223674277,
        0.5981734993824781,
        0.4784510066515474,
        0.36420496142432346,
        0.26030772471060043,
        0.18456167938968487,
        0.1425461464329796,
        0.10801612921057449,
        0.08570188093548521,
        0.07493750483683313,
        0.07083305210213219,
        0.04938649187046638,
        0.020876661832800448,
        0.004998670889788037,
        0.0031579246392823366,
        0.0011671094972822854,
        0.00572200590894705,
        0.008225247547479666,
        0.010980026244914181,
        0.008580316164457386,
        0.004932772282552378,
        0.002222015184423645,
        0.0016702743086350188
      ],
      "range": 1
    }
  }
]
