[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2637066 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2637066; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012099956163402812,
        0.02435322437891202,
        0.02522400046111853,
        0.00002420812903431313,
        0.002100959172049543,
        0.02371508714609342,
        0.05126451518467873,
        0.08360759268065342,
        0.12409351908522577,
        0.1206834413700681,
        0.09991296387727876,
        0.07126087098313048,
        0.042083011953436125,
        0.00005013405807818234,
        0.00005306175878798634,
        0.000058280141642264545,
        0.00008117036130305423,
        0.22603170720793486,
        0.5744993109766687,
        0.7401767342948564,
        0.7167648818800894,
        0.6512030415620997,
        0.5639696920744494,
        0.49073614388111636,
        0.42227225257160794,
        0.34943490227396656,
        0.2767812409700781,
        0.19000830089197615,
        0.10981989074221123,
        0.04411824732486786,
        0.034625855022210286
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2637066 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2637066; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016254160115825693,
        0.03144028628786689,
        0.06435494219712362,
        0.10643267176475674,
        0.15383304778871668,
        0.1897745448919367,
        0.23800303064087133,
        0.3185992690361181,
        0.42160308464027824,
        0.5298416118519597,
        0.667100102917409,
        0.8346657990357466,
        0.954281500728461,
        1,
        0.9888356984618512,
        0.933826836340084,
        0.8470463006993378,
        0.7081668414821624,
        0.5502629437412639,
        0.4094904716074607,
        0.30404730105351935,
        0.21994063478123033,
        0.1638394943471267,
        0.11318933617892006,
        0.07323117434300089,
        0.03783673218645267,
        0.018545250668735632,
        0.0028821114071471855,
        0.00002344061316629921,
        0.0033327764265285737,
        0.0003093939249150381
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus XZ 2 / prf-solomatov-pred-olympus-xz-2-7fb2ac7d46c6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2637066 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2637066; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04899482796410859,
        0.11537973641918707,
        0.27123904369477286,
        0.46111045381495946,
        0.5926269953046301,
        0.6878691697515344,
        0.7672909968882083,
        0.7981076317392132,
        0.7806792473150084,
        0.6887877284830944,
        0.5446996017543739,
        0.3928205437406572,
        0.25020545560861956,
        0.14444895956339357,
        0.09035217548593778,
        0.05332804336334395,
        0.03778906557515056,
        0.05109045052342262,
        0.07216017346551053,
        0.059681725827112404,
        0.02409507763552372,
        0.00010701663515437231,
        0.0010873006212207051,
        0.000014684566104905983,
        0.00014609594526644384,
        0.008282253838167114,
        0.012735436276528535,
        0.013185505027177932,
        0.008778702542901846,
        0.002037689045325373,
        0.007164634483930246
      ],
      "range": 1
    }
  }
]
