    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27823472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27823472; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014520858503927906,
        0.025739978101942132,
        0.027781550771233728,
        0.00004133727451412246,
        0.000005890083379960632,
        0.0035891512748660558,
        0.02561213963519722,
        0.04329927264289662,
        0.07295160359569791,
        0.06595443947469963,
        0.05837461622330959,
        0.057152813279377934,
        0.06059386477719243,
        0.052691328386335105,
        0.0454949691397249,
        0.06170807870419623,
        0.13839523694239167,
        0.349113870475978,
        0.5857805596655946,
        0.6481532211364563,
        0.5941481710118709,
        0.5124522561382706,
        0.41903884605055763,
        0.33597845013735167,
        0.2706973630034383,
        0.19696393390443867,
        0.1416691417951002,
        0.08695323142992363,
        0.04616023478306374,
        0.01803736176419679,
        0.004797134591973281
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27823472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27823472; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01721790508388026,
        0.02808467253835179,
        0.055098040963399535,
        0.0859781158871905,
        0.12020539348935315,
        0.14891237513420322,
        0.19272278456117914,
        0.28555109872700285,
        0.39623453176512263,
        0.5048548577977616,
        0.6441034389956796,
        0.8166654398847132,
        0.9464082340262926,
        1,
        0.9914281366466414,
        0.9333643551027708,
        0.8341542349567301,
        0.6983737687374171,
        0.5477766398097261,
        0.38304548763720075,
        0.22856306358890077,
        0.10940321898000364,
        0.05361152626818105,
        0.038083129955887605,
        0.04082040516007492,
        0.03162521737042739,
        0.04050601233375906,
        0.025208013938734893,
        0.01301780309804614,
        0.010167235778482282,
        0.00004332213643214621
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5 / prf-solomatov-pred-panasonic-dc-gh5-e1da4c0363fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27823472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27823472; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.042246805143513366,
        0.10480178749798012,
        0.2531766704026011,
        0.4446433212936186,
        0.5756546487081123,
        0.6605739211842433,
        0.7326956535115388,
        0.7693084098203129,
        0.7579235258633431,
        0.691921913986867,
        0.561001229465539,
        0.4091193938700389,
        0.2526453743803074,
        0.13470933102813337,
        0.08113273569883729,
        0.04939713850234076,
        0.0451218417313267,
        0.02993899179800422,
        0.007039793595853171,
        0.016372981775962397,
        0.055402833981323396,
        0.08634877056321368,
        0.08054537909575052,
        0.04330430795984053,
        0.000052046229169386195,
        0.000014130950299804424,
        0.00004655549817794127,
        0.00003239501885314672,
        0.000028742972839622604,
        0.000012276266240244927,
        0.015938179821698744
      ],
      "range": 1
    }
  }
]