[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27570873 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27570873; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0110669963189051,
        0.019997715342564597,
        0.023609472213665484,
        0.0027519273691478685,
        0.018362245185344694,
        0.028406184309071388,
        0.039216284518810846,
        0.046464850786552894,
        0.061684619126858985,
        0.06549971776374292,
        0.05978883222159849,
        0.055284865299695084,
        0.0526051170015545,
        0.03278765238953441,
        0.007526779438576356,
        0.002072817570919862,
        0.04683367842577926,
        0.24747442708832615,
        0.5308859461940142,
        0.6701360526378689,
        0.6447912621410282,
        0.5810947662049003,
        0.49870785738268064,
        0.42818060204332303,
        0.35814056377540165,
        0.29310366777287034,
        0.2260458092857633,
        0.1516234469615815,
        0.08414560177329168,
        0.03562783086338978,
        0.025417254651312636
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27570873 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27570873; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015307317254698463,
        0.02710581199224268,
        0.05138046952666315,
        0.0835560665779426,
        0.11419903171002238,
        0.13714283548438963,
        0.18560832658436313,
        0.2824010324228761,
        0.40064150308189367,
        0.5227570414618354,
        0.6711419692804069,
        0.8455608931933348,
        0.9623507387669589,
        1,
        0.9806553822216656,
        0.9171122002556829,
        0.8249761986136601,
        0.6891871360039996,
        0.5409981395946367,
        0.40145943148046126,
        0.28854220176488427,
        0.20294069034375514,
        0.14940734738432113,
        0.10524973946236668,
        0.07085347279355282,
        0.041958519050158474,
        0.02723976857751294,
        0.01174212474157057,
        0.005602387345514957,
        0.007844628278545986,
        0.0011943217394675895
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GH5M2 / prf-solomatov-pred-panasonic-dc-gh5m2-fcca81f8969e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27570873 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27570873; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.047068955705537506,
        0.11139918565509332,
        0.264122503484021,
        0.45024873169594587,
        0.5821636115766083,
        0.6738814545335579,
        0.7441623266698881,
        0.761945659101908,
        0.7298402556930279,
        0.6335224495793078,
        0.49183680183068557,
        0.34794801383329427,
        0.21869924104325605,
        0.12763143191004506,
        0.08658656546711452,
        0.056269150418269305,
        0.04543145949712945,
        0.044408579300336266,
        0.04627329718576557,
        0.034466808504757904,
        0.00914040262707677,
        0.00007626930783076764,
        0.000019562416467552552,
        0.00010005729960019763,
        0.000005600673217710589,
        0.004482261769513066,
        0.007357113066387125,
        0.007151011141359216,
        0.004009405868287159,
        0.0007057478013119134,
        0.0033246760086269303
      ],
      "range": 1
    }
  }
]
