    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27198833 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27198833; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013723513799286904,
        0.02438205933320742,
        0.02231346102239019,
        0.00037783176212008803,
        0.0004548572359703815,
        0.000012093654900561359,
        0.02722053552812358,
        0.05698158814387367,
        0.10286441701377408,
        0.10152316461518772,
        0.08581750547900345,
        0.0665460389421855,
        0.051144326670192065,
        0.013599201112783036,
        0.000044251082390189317,
        0.00012069582176558826,
        0.010510659041878746,
        0.2446444485320381,
        0.5945890031384803,
        0.7562644323747272,
        0.7324954346386846,
        0.6570185198754667,
        0.5634302765857638,
        0.48615902013148876,
        0.4141299371189933,
        0.333616262138894,
        0.2626160467987726,
        0.17945348243433826,
        0.10114130632001748,
        0.038491294828715626,
        0.027621098669931905
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27198833 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27198833; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018365996805818838,
        0.029167233020622612,
        0.05786112220329453,
        0.09082924624008684,
        0.13051442317396486,
        0.16196860357942564,
        0.20799017369605527,
        0.2971296967042667,
        0.41107565166490784,
        0.5265595034904622,
        0.66713924821701,
        0.8378413147358197,
        0.9567982567487362,
        1,
        0.9830315146241752,
        0.9231676226696932,
        0.8302602909470417,
        0.6966815451236456,
        0.5478483212864317,
        0.4058445669341769,
        0.28819454864111266,
        0.19801720904716757,
        0.14797945558914238,
        0.10840985346687484,
        0.07905016733622358,
        0.05170641696281601,
        0.039961754976766836,
        0.022182706515386154,
        0.010608144842096719,
        0.010452326392091897,
        0.0040723909000066295
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC ZS200 / prf-solomatov-pred-panasonic-dc-zs200-9a3e25cd69bc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27198833 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27198833; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.044770211280756055,
        0.11274873447695348,
        0.26713965999938305,
        0.4558980710679756,
        0.5788406436408503,
        0.655324660436718,
        0.715622651898337,
        0.7195452834318297,
        0.6693122458599603,
        0.5671699223271822,
        0.43191926653617824,
        0.30281788192897835,
        0.19452788654572054,
        0.12527155117280217,
        0.10172290112594169,
        0.09018837315556884,
        0.09635467080517755,
        0.10169996631840784,
        0.0970357809101589,
        0.07993333390443627,
        0.06530162158060238,
        0.049729832158607684,
        0.028632808253207038,
        0.007689840222188944,
        0.000015425772127796805,
        0.00009334290188112115,
        0.00004412037825299343,
        0.000026419112540600546,
        0.000037929366307738274,
        0.00003733389222986148,
        0.0013511632649827292
      ],
      "range": 1
    }
  }
]