[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27668568 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27668568; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012880935146336451,
        0.02166934696439657,
        0.02381101544539638,
        0.000602449284690122,
        0.0001964223663472573,
        0.010349876437407242,
        0.02988327404584148,
        0.04653473211913244,
        0.0759361308471042,
        0.07628632244357568,
        0.06462510094487,
        0.056137946857242486,
        0.05035718870597134,
        0.02777842460079611,
        0.000605006699298641,
        0.0011016054390671755,
        0.04924399050937511,
        0.2628036984060758,
        0.5704920832910471,
        0.709330782858007,
        0.6766828698904838,
        0.610625927586856,
        0.5213816631204043,
        0.44118723455438674,
        0.36417096107033803,
        0.28773964738616037,
        0.21744215313203055,
        0.14473793873249965,
        0.07964772517320015,
        0.03285319645021022,
        0.02284154857598702
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27668568 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27668568; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017027276944726596,
        0.027761534315762205,
        0.05324325783683493,
        0.08325574709901865,
        0.11719144626494583,
        0.14394860261651418,
        0.190295717508763,
        0.2809067856348764,
        0.3959469821495641,
        0.5132340061834787,
        0.6568511243516469,
        0.8300608112425624,
        0.9525293828000062,
        1,
        0.9857156322654647,
        0.9255792348920985,
        0.8310067221404448,
        0.6952647133743967,
        0.5439778813272881,
        0.39530672494507124,
        0.2722730717397445,
        0.17828157929965874,
        0.1279299384051968,
        0.09278120212076028,
        0.06529419592658356,
        0.0420338558901928,
        0.03486563525802998,
        0.01888373839947192,
        0.009756892369709919,
        0.010119478174656527,
        0.0033067651350803555
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FX150 / prf-solomatov-pred-panasonic-dmc-fx150-2aaa1b5f83e3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27668568 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27668568; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04380685693600045,
        0.10854201778711496,
        0.2611482097664035,
        0.44763805629550474,
        0.5740354180960865,
        0.6568715807771476,
        0.7208216558225926,
        0.7342051818511172,
        0.6930613467238348,
        0.5974763131940909,
        0.4591084005504008,
        0.32072158559127456,
        0.20011672812268422,
        0.12065902723986295,
        0.09304443945201646,
        0.07859120862344593,
        0.08329827550164504,
        0.0821571900649141,
        0.06728627227834849,
        0.04980043058245732,
        0.03934125539131624,
        0.028105483088246563,
        0.010101370623879054,
        0.00002220014638993966,
        0.000062708391702816,
        0.000049423913084334546,
        0.00001694389460271309,
        0.000023617338634944895,
        0.000015195887260952575,
        0.00004172626498053676,
        0.001198793157636492
      ],
      "range": 1
    }
  }
]
