    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26848385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26848385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01119658258774224,
        0.021865821724472437,
        0.023003233527826718,
        0.00006174426506473294,
        0.008928413012551777,
        0.024215699380055817,
        0.04931745429008113,
        0.07324337758118411,
        0.10630466599760097,
        0.11208325938413054,
        0.10166103100801034,
        0.08903120243545375,
        0.07386179094198775,
        0.04353094981318243,
        0.005401051124676586,
        0.0002610000191817869,
        0.03661391551111919,
        0.2530608451867775,
        0.5792905979260949,
        0.7299002155995602,
        0.7007351093929858,
        0.6376557845099435,
        0.5495263867826686,
        0.4772441992320953,
        0.4109889514769696,
        0.33833936752620314,
        0.27019144726954714,
        0.191146152738796,
        0.11477017332699899,
        0.04793120331073917,
        0.03509048682071565
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26848385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26848385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018325050091467326,
        0.030485986401044232,
        0.05949611121860775,
        0.09532726083896666,
        0.13832020063776648,
        0.17553039037543597,
        0.23287830906775212,
        0.3405623094275503,
        0.4690100354267119,
        0.5931157497927715,
        0.7293328444150364,
        0.8787762839366314,
        0.9756035605121126,
        1,
        0.9717851930386128,
        0.9070162693212273,
        0.8144592682204161,
        0.6852035979072856,
        0.5443353110438486,
        0.40676320009564815,
        0.29064414861452553,
        0.20088207912691955,
        0.14671670940356374,
        0.10142332583505487,
        0.070024282652383,
        0.04632785174974211,
        0.035091237331407454,
        0.019928664610552923,
        0.011776749700214742,
        0.008016958934401453,
        0.003458798210767612
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ18 / prf-solomatov-pred-panasonic-dmc-fz18-1ee7d2c7a6e8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26848385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26848385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04658514655537009,
        0.1151231666262235,
        0.27014626764328653,
        0.4531669595768981,
        0.577450673476263,
        0.6573145461077081,
        0.7163406663007849,
        0.727361589905687,
        0.6908874034695196,
        0.6046775997885906,
        0.48537399921820246,
        0.36830747920219403,
        0.25908549061703334,
        0.17722226122725815,
        0.1312409666354233,
        0.09114510612090819,
        0.06667034162390029,
        0.057268122458762415,
        0.05847254499665436,
        0.04184622278025289,
        0.014695697338964708,
        0.0029393144131388163,
        0.0017245700253478932,
        0.002569104622121591,
        0.011057541822347973,
        0.01658253671496442,
        0.0194984800761759,
        0.015531721554201489,
        0.009529493114762767,
        0.004709815879055667,
        0.002751343516565335
      ],
      "range": 1
    }
  }
]