[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26045498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26045498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013651772755506535,
        0.0213473483977922,
        0.01842652039135516,
        0.00019210610601494356,
        0.0002119562275215471,
        0.00004982192315923466,
        0.006231233512985622,
        0.03619693507108215,
        0.07542799143253087,
        0.07227940506263308,
        0.04920864250704671,
        0.02424344122734762,
        0.005189678461897714,
        0.0002264791596612973,
        0.00011451680824071783,
        0.00029814327220773433,
        0.000011628665345542634,
        0.21531425507778734,
        0.5603716235335565,
        0.7489693612308738,
        0.7364534938053402,
        0.6734290509630493,
        0.5874056621992791,
        0.5208188762603042,
        0.45523452843942547,
        0.37734285211210017,
        0.3017475803303895,
        0.2149609732937339,
        0.12166446577446897,
        0.04795966274094663,
        0.03228431262861628
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26045498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26045498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016322527601507177,
        0.028999806415680746,
        0.06134911684161309,
        0.11019469084445996,
        0.1596306586266847,
        0.18783284543071513,
        0.22579486097750942,
        0.29916214310818706,
        0.3924564237550766,
        0.5060143215537671,
        0.6501137739812078,
        0.8257260813365903,
        0.9512213588697748,
        1,
        0.9888001757539826,
        0.9312235074176735,
        0.8388486946957205,
        0.7008367434556252,
        0.5444552452020691,
        0.40430545808722873,
        0.29235029408921265,
        0.20854697422180218,
        0.1541700488890633,
        0.1077579587842782,
        0.07101529024325048,
        0.0403396203059738,
        0.025330517005280526,
        0.009923519220097078,
        0.0051296396789955795,
        0.005774628690148294,
        0.0004244813057519576
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ8 / prf-solomatov-pred-panasonic-dmc-fz8-d0b25f02ec1a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26045498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26045498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05219350768413029,
        0.12415043091132294,
        0.2845520941853368,
        0.47321195394305765,
        0.6134490882071059,
        0.7259941814128491,
        0.8140803834889239,
        0.8530189747187786,
        0.8379410138366331,
        0.7285757791999216,
        0.5589910010551535,
        0.37444402099741003,
        0.21049385579035576,
        0.09235000997101303,
        0.05020081013617018,
        0.030379204114277258,
        0.048746804534127164,
        0.06576365328088563,
        0.06464891168523634,
        0.051104739867135575,
        0.049506912864557245,
        0.04215965845613703,
        0.030554040471792863,
        0.0024746570405372935,
        0.000020120099834528025,
        0.000017131746914572335,
        0.00004998154191561244,
        0.00001645007517230041,
        0.000017646527626386718,
        0.000012443481019253308,
        0.000008761183986576106
      ],
      "range": 1
    }
  }
]
