    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26418564 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26418564; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013490482298735087,
        0.023045047792908047,
        0.027001844990515004,
        0.0000012940080316250345,
        0.013156649241041261,
        0.026960407461965003,
        0.0397961600032462,
        0.04575653695636144,
        0.06329982583459116,
        0.057241763783981596,
        0.04584480064851367,
        0.039497347395566235,
        0.03881023586293335,
        0.02128138001747559,
        0.00013307715741097813,
        0.0001872800959204293,
        0.05194317526115349,
        0.26209219774398035,
        0.5722593400610267,
        0.7326068139055552,
        0.7155664100440886,
        0.6444446412757332,
        0.5524546678615839,
        0.47494572377211725,
        0.39857639499255143,
        0.3171350267183334,
        0.24529573219801046,
        0.1646221800700447,
        0.09097730292986402,
        0.034127850400952904,
        0.022876470500062
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26418564 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26418564; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01805959248958422,
        0.030880512657690252,
        0.062149608131615325,
        0.09907075191520628,
        0.14221084461668695,
        0.17982451657856952,
        0.23136556551673285,
        0.3230510560679983,
        0.435548805756437,
        0.5465526438151597,
        0.6806068263210673,
        0.8463237820193407,
        0.9616438652759477,
        1,
        0.9811587412548238,
        0.9188662184666813,
        0.825176304056496,
        0.6974335168255171,
        0.5632218692885805,
        0.42514067002279154,
        0.30250080965793597,
        0.20513663043911093,
        0.14781879893244765,
        0.10880355949702641,
        0.08050900495575762,
        0.05731014751596643,
        0.045928832467957,
        0.027921316995125095,
        0.014904984994642404,
        0.009847669994478125,
        0.005055881916973232
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GF5 / prf-solomatov-pred-panasonic-dmc-gf5-0a7c3f144ae4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26418564 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26418564; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04824963612708094,
        0.11862524776138476,
        0.27867170978710276,
        0.4683354856077719,
        0.6019382809754535,
        0.6988184142029824,
        0.7775508540131099,
        0.8067085705339624,
        0.7825323132627496,
        0.6885537381971254,
        0.5461190093450954,
        0.39450993627057096,
        0.2503798465351864,
        0.15391417943836766,
        0.11396024401629097,
        0.09481399518914048,
        0.09685935617091072,
        0.08125118004142845,
        0.043035261114116576,
        0.02015237467108356,
        0.021654225793650252,
        0.024212766447108937,
        0.02210782274161457,
        0.000014593880272977744,
        0.000008311394972111277,
        0.000043410228504471325,
        0.00006454189183030538,
        0.00002525172677818522,
        4.783957977428296e-7,
        0.000044744547811152794,
        0.0001130837807838458
      ],
      "range": 1
    }
  }
]