    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2734399 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2734399; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.00793340145311639,
        0.023095796553465678,
        0.02321488743961653,
        0.0002711293560303379,
        0.000018428501838978143,
        0.0011888692908386814,
        0.02558393636042143,
        0.0514133123951552,
        0.08719883235767713,
        0.08939359983674657,
        0.07778862923808852,
        0.06913484096505301,
        0.06311221588363658,
        0.0379295633153757,
        0.0042141333433781975,
        0.00013940926324212377,
        0.044110987460132915,
        0.2813308518617802,
        0.607861508141277,
        0.7422818688859966,
        0.7042230120768768,
        0.6328103177334397,
        0.5417199172468978,
        0.4608960140784136,
        0.386322954331098,
        0.3095538361446153,
        0.23583544318148156,
        0.1559872023066129,
        0.08667224132249901,
        0.03482768242674167,
        0.023871962358090387
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2734399 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2734399; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01722919990827966,
        0.029182540660671687,
        0.05699272125245803,
        0.08859489050427534,
        0.12422420063787325,
        0.1544848063504997,
        0.20401106787999848,
        0.29819510612752564,
        0.41652198526988926,
        0.5332513652908738,
        0.6736802492979261,
        0.8424931401744954,
        0.9589460060510554,
        1,
        0.9846401348157309,
        0.9201839965564645,
        0.8258193848081424,
        0.6924275864641554,
        0.5442478950584753,
        0.40071176518130674,
        0.27670628902365746,
        0.1833571947619934,
        0.12964583076573682,
        0.09559630470900551,
        0.06903599291837072,
        0.047545358230455755,
        0.03927140845209496,
        0.02394445726464938,
        0.011476070244320596,
        0.01103160584830524,
        0.0013659937704775344
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS50 / prf-solomatov-pred-panasonic-dmc-zs50-05135ba31b03@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2734399 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2734399; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045269245636792584,
        0.10857040614774947,
        0.25742314856025034,
        0.4458277120493388,
        0.5738649333912132,
        0.6556186569699594,
        0.7144123443579374,
        0.7213589165297384,
        0.6726130312364801,
        0.5788163687889002,
        0.4484390537006486,
        0.3241988093178793,
        0.2172119540710774,
        0.14588629896368452,
        0.11875416133490392,
        0.1050428375668657,
        0.10543764095876278,
        0.10184805509364214,
        0.08969625500887031,
        0.07022862062193556,
        0.058358381494434425,
        0.04570535243759232,
        0.028086126421198954,
        0.010462809560711512,
        0.000006833337051395937,
        0.000014362219997886191,
        0.0000041798274502002086,
        0.00003769673335895749,
        0.000021471461919054244,
        0.000006411036940841479,
        0.000789680108864873
      ],
      "range": 1
    }
  }
]