    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496945169811 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26338094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019995045436848997,
        0.031159824726987716,
        0.0328273324236316,
        0.00035549158868784385,
        0.0002971743159615809,
        0.011933428305193398,
        0.042504811703039574,
        0.0688256460031828,
        0.1120155310181772,
        0.11064076936142264,
        0.09206660770517411,
        0.07181610534662582,
        0.05064271362700266,
        0.007817824630742072,
        0.00016509851064365523,
        0.00004845518655153323,
        0.002797914306175686,
        0.2530363874430221,
        0.5784769528907052,
        0.7129391039303459,
        0.6743601112517861,
        0.5966695136597552,
        0.5031523480290441,
        0.42812739552458073,
        0.3602414214891556,
        0.2887448870416772,
        0.21750438092836294,
        0.14043616653596425,
        0.07455169139734838,
        0.029024728334115815,
        0.021397556086307102
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496945169811 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26338094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0220732249076186,
        0.03847874081863808,
        0.0722457493733312,
        0.1162883661439074,
        0.1583067687744672,
        0.19310048952078476,
        0.2513714025940823,
        0.3535540783223027,
        0.47776477216486,
        0.597301431337361,
        0.7290679173671413,
        0.8851233323645882,
        0.982418241805956,
        1,
        0.9657813367068107,
        0.8906613108478056,
        0.7902664021821125,
        0.6502983300105031,
        0.4994316335246138,
        0.366119663411084,
        0.26237679980436956,
        0.1829456241557054,
        0.13376344924579583,
        0.09397894131884375,
        0.06240885943569037,
        0.03778192705037221,
        0.023925257012972094,
        0.011404601525642872,
        0.005103120391279017,
        0.005907015073333308,
        0.001396774676037139
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Parrot ANAFI Ai / prf-solomatov-pred-parrot-anafi-ai-1effd6dd05ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000496945169811 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26338094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06175070081001306,
        0.14263276948756817,
        0.3328857905533006,
        0.5665416748976632,
        0.7132367250679152,
        0.8006628000070503,
        0.8591188811090918,
        0.8555932993739354,
        0.7938644085888168,
        0.6751706963042247,
        0.5225390561670864,
        0.3836219567316733,
        0.263034396987,
        0.1820313573184149,
        0.14444327714492597,
        0.1164665163145615,
        0.10256146931675683,
        0.09704750978137291,
        0.09237309929920491,
        0.06790761790617095,
        0.03876970975955967,
        0.017568963350070865,
        0.005823865387991176,
        0.0010729799877613685,
        0.000007022726788098257,
        0.00030469447205078116,
        0.0010090709901372928,
        0.0005945104659932275,
        0.0005046055272193777,
        0.00018636275808643212,
        0.00021265400374074144
      ],
      "range": 1
    }
  }
]