[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000488845415094 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25908807; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018349136502116826,
        0.03103356427476854,
        0.029652260164440825,
        0.000013088009605526063,
        0.000027553267803001223,
        0.000003832397154458799,
        0.0374191510648668,
        0.07566280848545669,
        0.12641661216782385,
        0.13460838916705828,
        0.11907768018805343,
        0.09493799972205226,
        0.06832444628993116,
        0.013700615779028343,
        0.0000012852019742710425,
        0.00019683379491909305,
        0.00011260694239993374,
        0.230837404899802,
        0.5944061561503139,
        0.7414039715058921,
        0.7015248708029409,
        0.6174696617672116,
        0.5216401654837963,
        0.451530281600188,
        0.39049523066133457,
        0.3240659185296157,
        0.2557033475844017,
        0.17377676460455627,
        0.09674605354896366,
        0.03624374466594492,
        0.030668880111472736
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000488845415094 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25908807; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024838639424810256,
        0.04038911593868824,
        0.08037348963819063,
        0.12962108293640198,
        0.18124715538549566,
        0.22593264985145783,
        0.2885991020266818,
        0.3964685436393657,
        0.5229857529719527,
        0.6381413423455206,
        0.763790328130508,
        0.9054071565128338,
        0.9904997265987584,
        1,
        0.9605445060524098,
        0.8853877567226816,
        0.7888996607821975,
        0.6628261538532763,
        0.5302249473542415,
        0.40301586461458017,
        0.2985314419661752,
        0.21663108926502142,
        0.16334529139192933,
        0.11531318913698967,
        0.07899354286169949,
        0.04992289841828688,
        0.03472530484372056,
        0.01885874564560344,
        0.008033621966052382,
        0.006748809911558678,
        0.003531561929060316
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX MX 1 / prf-solomatov-pred-pentax-mx-1-89c4270aa67b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000488845415094 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25908807; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0590473524118652,
        0.14520083695770358,
        0.33985902021288594,
        0.5719523400169553,
        0.7112385042029775,
        0.7873992002453494,
        0.8359836667995121,
        0.8217630209927573,
        0.7499626695470771,
        0.6345638999219415,
        0.4948059090486104,
        0.37238645621658345,
        0.2675718835090144,
        0.1912815206041714,
        0.15020699332084259,
        0.11524463764562584,
        0.09210444513547623,
        0.0802006413047928,
        0.0717424701210274,
        0.04731231889538761,
        0.021505883404820604,
        0.00839916964952636,
        0.004776189269067538,
        0.003215892137764534,
        0.0025797307130447956,
        0.0034471073336331008,
        0.004468698096178319,
        0.0029794062898115467,
        0.0012713087245720322,
        0.0004635390555626985,
        0.0005913014151078875
      ],
      "range": 1
    }
  }
]
