    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27731246 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27731246; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008846588429528195,
        0.017002705179565317,
        0.01705781629862575,
        0.00025752410836498297,
        0.0017197796305294037,
        0.0069348081222170834,
        0.01669459244636898,
        0.03137329278316597,
        0.05529976907636967,
        0.06691275249586695,
        0.07890138077459628,
        0.09529479129787388,
        0.11236678654828565,
        0.12536144246818193,
        0.1283481636562598,
        0.14444577066605663,
        0.19169318969656104,
        0.3078015679497416,
        0.46203210631069375,
        0.5469535699910492,
        0.5258914438968952,
        0.472853329417654,
        0.3991749955988274,
        0.3274048558798981,
        0.25992434670984493,
        0.19385949336715705,
        0.14486926407850553,
        0.09237067818734146,
        0.05099316489421356,
        0.02142742269856897,
        0.00956743414991162
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27731246 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27731246; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017765546849211177,
        0.026626704764726405,
        0.051801787052770734,
        0.08116770158830945,
        0.11171634336228528,
        0.13718211579818665,
        0.1853286541830829,
        0.28120854721060856,
        0.3943434781112973,
        0.5106528570696031,
        0.6589450758902071,
        0.8352225861037762,
        0.9588188716799816,
        1,
        0.9749223673541391,
        0.904011381241218,
        0.8043021218736439,
        0.6819341979801413,
        0.5524091128108705,
        0.40651550240476036,
        0.26984741327526357,
        0.16671289851166443,
        0.11040234542652719,
        0.08278300946160155,
        0.0659944958838128,
        0.050467945075385365,
        0.050884742070370734,
        0.032913584193079534,
        0.016551350415340154,
        0.011061403443610144,
        0.0021247361189612613
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ180 / prf-solomatov-pred-phase-one-iq180-17e0cff1085b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27731246 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27731246; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045213954684906695,
        0.11284739964442998,
        0.269672736666791,
        0.4584235775053166,
        0.5951220511332236,
        0.6967121131160137,
        0.7804214783569408,
        0.8219312251602399,
        0.8217533031151937,
        0.7392256013307156,
        0.5922952398172084,
        0.42084499196321723,
        0.2517535057746774,
        0.1250352616683722,
        0.07095364917970148,
        0.034721162547113826,
        0.026788368975559196,
        0.018714386652514643,
        0.011207585118966527,
        0.01575827750401118,
        0.027962729839113614,
        0.03398567810476313,
        0.028147294932221942,
        0.01769442779455348,
        0.00010108108737703312,
        0.000021050663572779963,
        0.00004690956187111102,
        0.000054746497867423626,
        0.00035487288959176234,
        2.5053228765847737e-7,
        0.006685437791002973
      ],
      "range": 1
    }
  }
]