    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2751282 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2751282; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008778581766609167,
        0.012116358846530454,
        0.010320273603360179,
        0.000054058700634831324,
        0.00005480759515018817,
        0.000015797852419344872,
        0.000023144279648542025,
        0.02519217477525023,
        0.06528747689259044,
        0.08757455978703747,
        0.11041918276643398,
        0.13055032526654847,
        0.14378087015434987,
        0.1571100454260959,
        0.16084779023015452,
        0.1727691090916889,
        0.20214152166153818,
        0.2700096536814474,
        0.3654857626371997,
        0.42543232573033224,
        0.40592289340024035,
        0.3599295164944924,
        0.3073266935196029,
        0.25388753315727,
        0.2012576173580171,
        0.14920715869910828,
        0.11152960329039337,
        0.0703755521971212,
        0.03987297558011138,
        0.019618910747789577,
        0.007629079098398492
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2751282 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2751282; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016791255858178117,
        0.027577866245626585,
        0.052759851589186425,
        0.08507257707497815,
        0.11863746791495748,
        0.14069992098229117,
        0.1808595047690495,
        0.2618294089809769,
        0.3640887193679165,
        0.4749534217139501,
        0.6236338914004453,
        0.8050373607649088,
        0.9432561256897694,
        1,
        0.9822229782334199,
        0.9208022296514862,
        0.83246075829377,
        0.7311997098080095,
        0.6349128151894281,
        0.5039588090206675,
        0.36664259061775567,
        0.25321150649042884,
        0.18698526723178505,
        0.14812053071986078,
        0.12403717612371251,
        0.0973388296801273,
        0.08655594010355899,
        0.05665136834392113,
        0.03193955763167862,
        0.0176190517729553,
        0.006762427479262395
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ280 / prf-solomatov-pred-phase-one-iq280-8e03a13a95a0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2751282 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2751282; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.049504670913414185,
        0.1255958131518325,
        0.2873657080590067,
        0.46442901890827626,
        0.6002108835081247,
        0.7176865548497029,
        0.815078497951137,
        0.873038459888881,
        0.8866785738430303,
        0.7961476140940842,
        0.6303259353276037,
        0.427731632017365,
        0.2304486781071515,
        0.0840089601865603,
        0.02847842932858209,
        0.00010449644565697009,
        0.000034941598134978534,
        0.000010386909448031864,
        0.001287482962488033,
        0.00016907148013180765,
        0.02415589750523574,
        0.04066069563207261,
        0.031589211865595754,
        0.010248410013949862,
        0.000058837414703400085,
        0.0000074837566632573475,
        0.0000502810362587332,
        0.00011591369405244538,
        0.00004119433776690285,
        0.00008235481495535536,
        0.002254299995420317
      ],
      "range": 1
    }
  }
]