[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29383147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29383147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007200744018331325,
        0.0124623121546511,
        0.017887465559764584,
        0.010565289687997002,
        0.02636214630107524,
        0.03127939971848488,
        0.036297633469961545,
        0.036220575692590046,
        0.042759402183843685,
        0.04921768250351129,
        0.06528633573524308,
        0.09308434865741237,
        0.12528001170194603,
        0.15617363926335054,
        0.17511926139157255,
        0.19751313567603906,
        0.23325315018163303,
        0.2890500939194839,
        0.36235922585147196,
        0.4095552801066544,
        0.3860573715946764,
        0.33899333519312963,
        0.2772095310281094,
        0.22035114210196752,
        0.1658016821683532,
        0.11771229609952945,
        0.08239756279339311,
        0.049312430693689825,
        0.027382485613266682,
        0.010295855307806207,
        0.004362585464382015
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29383147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29383147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0161494182362427,
        0.023262593349854595,
        0.04244354765675712,
        0.06808636597026181,
        0.08686916346979444,
        0.10288360875708787,
        0.14902709366018554,
        0.25062224955005674,
        0.3665472251831977,
        0.48555694187555887,
        0.6441075899732592,
        0.8304786413790192,
        0.9590999221424444,
        1,
        0.9692430153924629,
        0.8873367784601154,
        0.7761655005843997,
        0.6287829891059661,
        0.4714529046191002,
        0.30781410173661794,
        0.16694124016055872,
        0.06479998211219513,
        0.025664678803805463,
        0.016892938663105077,
        0.01752116034405709,
        0.014490850826836214,
        0.028327551163937613,
        0.021323982077209088,
        0.009454426375772481,
        0.013099553291551788,
        0.0036447716100661376
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ4 150MP / prf-solomatov-pred-phase-one-iq4-150mp-85a4c1c06ded@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29383147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29383147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.042008179042224446,
        0.10868400175107182,
        0.2596357701236018,
        0.4309518650265747,
        0.564210089545548,
        0.6701561612852429,
        0.7565278831433543,
        0.8020915867180599,
        0.8050399775081954,
        0.7231051527598457,
        0.5753512379051843,
        0.40380501108339417,
        0.2365059807923229,
        0.11159716826791903,
        0.059619209610189135,
        0.026970368422415746,
        0.01925631723518247,
        0.015138004108273359,
        0.009369957547433567,
        0.016729947272155703,
        0.02573221990142853,
        0.03504183877921586,
        0.02476956671795571,
        0.013299050642873619,
        0.000030353630943615404,
        0.00002538490005852675,
        0.00004793525690083503,
        0.00007523261548533247,
        0.00004120826132068155,
        0.0007519793233856129,
        0.0026154433696295365
      ],
      "range": 1
    }
  }
]
