[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506921924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0190474524434599,
        0.029322521968494573,
        0.036121134936378044,
        0.0003257182934821515,
        0.018906599436679487,
        0.037642733019335614,
        0.06491999006547301,
        0.08733716848627462,
        0.1192598101892212,
        0.11801955106765853,
        0.10436622177908235,
        0.08909088240886691,
        0.07549678391916405,
        0.046511993101390106,
        0.008643003124898702,
        0.00009911155459837476,
        0.03939534007278451,
        0.23606490051808646,
        0.5357348503559309,
        0.6715946467777016,
        0.6298295021080864,
        0.555380058045081,
        0.468121461660741,
        0.39634581033230415,
        0.3326478422331197,
        0.26369432935350157,
        0.20413393994205178,
        0.1386483934644598,
        0.07722180301517907,
        0.029336273063821146,
        0.022601961851741372
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506921924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02488875582120457,
        0.04033610524261195,
        0.07736086594421816,
        0.12195510449976248,
        0.17110790346656243,
        0.21516629254614436,
        0.2781068438752607,
        0.3890511620962181,
        0.5205772899095299,
        0.6408874871010015,
        0.7725435043363084,
        0.9140699883482528,
        0.9933768788938123,
        1,
        0.9549259273789068,
        0.8739292732369779,
        0.7690320999739912,
        0.6358895775143294,
        0.4923943667109318,
        0.3589862619356899,
        0.24832689988134823,
        0.167864771021823,
        0.1199997098716363,
        0.08185854363036872,
        0.054221869991274006,
        0.03498861671761581,
        0.026073496988764277,
        0.013965547545400591,
        0.008470476588901052,
        0.004796192953345223,
        0.0030645835113052755
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506921924528 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05937686070297305,
        0.14572669384205464,
        0.33606739091024895,
        0.553155179928379,
        0.68882823856663,
        0.7725428117027999,
        0.8266770425864818,
        0.8216955495647468,
        0.7682527581127014,
        0.6570679766420516,
        0.5140678818389732,
        0.37786481806355454,
        0.25682182814593735,
        0.1702810324480767,
        0.12124871041398025,
        0.08347099290094717,
        0.060807676984064175,
        0.051421739238837215,
        0.05056642126903267,
        0.03480882041885915,
        0.011814836519923069,
        0.0009769702176753445,
        0.0002539857499379119,
        0.00021324789186543934,
        0.003949861833975996,
        0.00696814634153576,
        0.009346994946165775,
        0.007102118448691801,
        0.0039141878680925835,
        0.0011013025453901679,
        0.001175256131512493
      ],
      "range": 1
    }
  }
]
