[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000526307660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015456051398088196,
        0.02763327838917131,
        0.03375162685104811,
        0.00941486148496766,
        0.020054975572955477,
        0.03814658096251694,
        0.04825948146830614,
        0.04515568105929514,
        0.04961239856920381,
        0.0251395558385753,
        0.0014896950567617636,
        0.0000072086655163496755,
        0.000011569947354957564,
        0.000010315119150123325,
        0.00007507778774582831,
        0.015132745729540644,
        0.07389210057012044,
        0.23882272201786622,
        0.45631199786795196,
        0.5678288262091303,
        0.5439426180143478,
        0.4815437490548999,
        0.4078083245214413,
        0.3549462314513504,
        0.29196094379440735,
        0.22971068333113187,
        0.17473398214914063,
        0.11934516794676153,
        0.06830845798464262,
        0.029002389399387853,
        0.015081256562847319
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000526307660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021285036003405138,
        0.03318004888987983,
        0.06693656813995352,
        0.11251786880056086,
        0.15791725998586495,
        0.17951758892219,
        0.2091883074943526,
        0.28085914433195136,
        0.3740748089412943,
        0.49025646806826845,
        0.6400773261754567,
        0.8235861989533056,
        0.951873048102472,
        1,
        0.9713943312381464,
        0.8988799089091385,
        0.7831363171906327,
        0.6320338619418752,
        0.4769854964863339,
        0.3291976804835476,
        0.20285872321039283,
        0.11103712319651467,
        0.07078374843631806,
        0.05323161725675915,
        0.04001765808405486,
        0.026772953977389893,
        0.025721285984662855,
        0.014600891783562638,
        0.007502019150220752,
        0.006891995724186844,
        0.00010097349027842047
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000526307660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06720542975688298,
        0.15899676355489023,
        0.3575160814608715,
        0.5649825635248966,
        0.710509928572389,
        0.8255956004465969,
        0.9121588189858999,
        0.9270500291883712,
        0.8778834237412705,
        0.7241937425201708,
        0.5264617273503774,
        0.3253596282127171,
        0.16288286577196073,
        0.061705768912121345,
        0.0431249308915776,
        0.04466866737475513,
        0.07139664952717284,
        0.07132246159560493,
        0.04257349566313789,
        0.02482955451644589,
        0.03111849063389496,
        0.03345694085028103,
        0.018369241621361488,
        0.000009389063175468184,
        0.000017574401597856564,
        0.000010729877879846764,
        0.0000056379331855342985,
        0.0000064345043976668815,
        0.000004786037568763612,
        0.000002912308807520727,
        0.000018368484849304264
      ],
      "range": 1
    }
  }
]
