    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28239626 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28239626; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011715250761465467,
        0.017274813058784845,
        0.00646749181451624,
        0.0000292045581623496,
        0.00002001259790055293,
        0.000003123625291638069,
        0.000001664459260189919,
        0.000004496711110834117,
        0.027553534880384038,
        0.049777504135500944,
        0.06235289022595412,
        0.07959298044527927,
        0.08943744509930832,
        0.08145443215147395,
        0.05598112382933117,
        0.05184047055014114,
        0.10581577107288885,
        0.32624174980221055,
        0.6108472187273302,
        0.7252787625445181,
        0.6915272532292035,
        0.619755162479843,
        0.5279435357961185,
        0.44691059293773927,
        0.3739257949096068,
        0.2951322726441207,
        0.22533648285568653,
        0.14660010015713382,
        0.08044093430982407,
        0.03162900953433307,
        0.021665341460258718
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28239626 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28239626; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017476651425907694,
        0.025249673278250923,
        0.04298965220006809,
        0.06288400207566489,
        0.07858604784638437,
        0.09934966206705428,
        0.156224731871449,
        0.27278622599321956,
        0.41650208115362436,
        0.5510061641751205,
        0.6988818477978426,
        0.8626835921977154,
        0.9698533542901737,
        1,
        0.9706207865500769,
        0.8997914136681555,
        0.7996219213384766,
        0.6692717176920119,
        0.5261127750062978,
        0.3822637204897827,
        0.2549601400528463,
        0.1598063444607942,
        0.11173627086987625,
        0.08100371088483961,
        0.06125784031275768,
        0.0434605012120203,
        0.037870696304547376,
        0.02117725496789511,
        0.012429189395072017,
        0.011332832099121993,
        0.005552457033248245
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH S10 24 72mm F2 / prf-solomatov-pred-ricoh-s10-24-72mm-f2-c8cbd245c9ae@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28239626 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28239626; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04111537808609788,
        0.10310498092290599,
        0.25060455828983,
        0.4338153770166786,
        0.5471765100571799,
        0.6126113709862872,
        0.6535006518854038,
        0.6378264712145975,
        0.5721017693364635,
        0.48381540180454236,
        0.3708888354257949,
        0.27302217104433324,
        0.1942218214929617,
        0.15021507366988499,
        0.1347404282195522,
        0.1268756356759116,
        0.12234065351998642,
        0.10832248982334255,
        0.09092272326836057,
        0.0735350850609707,
        0.0647885103010925,
        0.053061609243691826,
        0.03706582020597581,
        0.019648823252829198,
        0.006103263194774605,
        0.0025495569240187527,
        0.0009083654294855036,
        0.0015045776456104624,
        0.0009534511186515005,
        0.00018926898677765775,
        0.0017838276965849336
      ],
      "range": 1
    }
  }
]