[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26768965 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26768965; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0142587145225824,
        0.022999465986077532,
        0.021559653128165397,
        0.00012087902539377223,
        0.00000793527952985855,
        0.0000374388737106571,
        0.02458704697772215,
        0.052998541407932656,
        0.09573519185370073,
        0.10193806148276557,
        0.08973883749334349,
        0.07605673958630825,
        0.056998251519997135,
        0.01681091966013628,
        0.000149819064726634,
        0.004747252648729602,
        0.01833775418661125,
        0.28697450573826816,
        0.6246511211770794,
        0.770417384459952,
        0.7461621695123438,
        0.6695917081590566,
        0.5714441705161182,
        0.48958134914816465,
        0.4172737496574858,
        0.338031799137546,
        0.2614737626202582,
        0.1775587214522489,
        0.09835236438913496,
        0.04008750058136353,
        0.029663246225619857
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26768965 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26768965; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0174732754889851,
        0.028380124147496924,
        0.05510901149895037,
        0.08384330137530532,
        0.11482800324928513,
        0.1455223614360884,
        0.19774192240902852,
        0.299987018549279,
        0.42677249568670284,
        0.5498673183666234,
        0.6877785898707701,
        0.8514545855620491,
        0.9628190705169213,
        1,
        0.984927358977084,
        0.9253996185508105,
        0.837748900639229,
        0.7005378056267771,
        0.5471688203111328,
        0.4054260596179195,
        0.29242215752458117,
        0.20383086906796732,
        0.15078700278475468,
        0.10624931894079581,
        0.07032380594468259,
        0.04093793689819535,
        0.02503016833112524,
        0.00980681173142107,
        0.0034857511300866507,
        0.008273465933404597,
        0.000025783119743329635
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy S20 Ultra Rear Main Camera / prf-solomatov-pred-samsung-galaxy-s20-ultra-rear-main-camera-2b89c05b22f5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26768965 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26768965; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04454824458099146,
        0.10943588592237316,
        0.2596407070650658,
        0.4491938705885715,
        0.5727297637394647,
        0.6544775638505261,
        0.7132713573348839,
        0.722777776428786,
        0.6800366768009148,
        0.596358693733583,
        0.47522662904598667,
        0.36056918898433316,
        0.25871724962096965,
        0.18915897570189955,
        0.15556158409561222,
        0.12968549960747455,
        0.11718148236213091,
        0.11528035170579064,
        0.11387652081430866,
        0.0881802228812358,
        0.05463364758405863,
        0.027842994303291145,
        0.007925900758583682,
        0.0015050681264666005,
        0.0023119948791445618,
        0.002756921681506924,
        0.004950876509420518,
        0.003965369972279466,
        0.0012173290973334233,
        0.000015915938475768488,
        0.002394172355935315
      ],
      "range": 1
    }
  }
]
