    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27001953 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27001953; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015179083527772972,
        0.02442200236405122,
        0.022083701501146972,
        0.00017564583569195904,
        0.00004025634738346518,
        0.00007066405529999997,
        0.02584553791349833,
        0.060034194563630267,
        0.10298583957982595,
        0.10473351316476996,
        0.08696567244598936,
        0.06720152057149346,
        0.04596096623085004,
        0.00610811040223646,
        0.0005358167240717736,
        0.00008797494018303046,
        0.003641703620475156,
        0.2674092499901766,
        0.6324411423129283,
        0.7772331505058171,
        0.7404040737349628,
        0.6729551377265193,
        0.5779796742850415,
        0.5007774807992592,
        0.42973769341795387,
        0.3514560965275364,
        0.27493177993458473,
        0.19154247842739375,
        0.11152494414015163,
        0.04824922108411936,
        0.03475694147012255
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27001953 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27001953; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017337049657111837,
        0.029018293602688667,
        0.05491388345131924,
        0.08403362156803991,
        0.11609191749944901,
        0.14499762294971777,
        0.19183601275063325,
        0.29025544930027836,
        0.4126480962321503,
        0.5348550528919148,
        0.6775132154329725,
        0.8424216574260387,
        0.9592867967735519,
        1,
        0.9842444359487628,
        0.9256117881547308,
        0.8343138735187043,
        0.6978903340806496,
        0.5448936600993268,
        0.4032928284854062,
        0.2949040389782176,
        0.20881356248564686,
        0.15842144084911192,
        0.11393996574988483,
        0.07606050569749528,
        0.04606636786605769,
        0.03230924074269739,
        0.014024056704342829,
        0.007361350862287628,
        0.00718363297647396,
        0.0003208673091164924
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung Galaxy Z Fold4 Rear Ultrawide Camera / prf-solomatov-pred-samsung-galaxy-z-fold4-rear-ultrawide-camera-3bb4206f2a26@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27001953 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27001953; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04622347502049204,
        0.11382084103323933,
        0.2709121817966278,
        0.46062690354286595,
        0.5781405515371425,
        0.6526389405981116,
        0.7052349509681763,
        0.7005368093189407,
        0.6409630073795033,
        0.543759890256827,
        0.4207564912063953,
        0.3122328596009333,
        0.22652472582260993,
        0.1720952443699165,
        0.15197729216105219,
        0.13760213196430643,
        0.13314044358198832,
        0.13113673666493678,
        0.12402000329383582,
        0.09573592695313557,
        0.06341669434059084,
        0.03619718914405932,
        0.014408642960011077,
        0.0020942207402553435,
        0.00006421970662640587,
        0.0000852911083876044,
        0.00031910188126021847,
        0.00012123687127371862,
        0.00033014171234206646,
        0.00007971880034010873,
        0.0016656228532802792
      ],
      "range": 1
    }
  }
]