[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28627285 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28627285; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010570585719183638,
        0.01782288261006938,
        0.02312575328048049,
        0.008243402753701582,
        0.015730259785376084,
        0.02240743402666372,
        0.024234806060022804,
        0.018201870697832502,
        0.01813462925317577,
        0.007560984214884506,
        0.0000046658720867172695,
        0.000002903049905011949,
        0.004278800452086183,
        0.008938109219927772,
        0.009046647280732349,
        0.01894423100199687,
        0.07185503620060373,
        0.24308035148984614,
        0.4659496700438061,
        0.5873794877858658,
        0.575165964917735,
        0.5236466888145347,
        0.45267422321047907,
        0.39750748280879583,
        0.33046064270502773,
        0.265851581803863,
        0.20268326179028154,
        0.13595183755637322,
        0.07857326323470773,
        0.03414866621127361,
        0.01916475697922454
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28627285 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28627285; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014624972993422183,
        0.0225477386346627,
        0.045882087665665816,
        0.07827534116490613,
        0.10668802857134373,
        0.11682247897416748,
        0.1432499100071837,
        0.21642805107085772,
        0.314005309969143,
        0.43743145743649803,
        0.5998491648788908,
        0.7934160364840745,
        0.9378083531148691,
        1,
        0.9867317840305149,
        0.9241684637575656,
        0.8187919322422645,
        0.678458715173304,
        0.5300865939609711,
        0.38025418756965595,
        0.2482297220990394,
        0.14987292717419762,
        0.10591684122332941,
        0.08627053875350037,
        0.06559565463507978,
        0.044929622211816456,
        0.04095752007219685,
        0.024950668566718775,
        0.010631836026364357,
        0.011458566189563557,
        0.00320505664438664
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX20 / prf-solomatov-pred-samsung-nx20-76d8fc6440dd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28627285 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28627285; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.046310832480271874,
        0.11374292043412429,
        0.27112761828444437,
        0.45436425424206306,
        0.5914322647083018,
        0.6990893827339896,
        0.7794614822886626,
        0.7939089578351561,
        0.7462148436360625,
        0.6109936377131118,
        0.43508051846341694,
        0.26220149762717626,
        0.12971387262187106,
        0.05104680726796131,
        0.04334102587793428,
        0.05271899168922236,
        0.07741329644079066,
        0.07529150249491001,
        0.04791597945805898,
        0.03415888373626769,
        0.03584149876595003,
        0.03236712458062299,
        0.015381268604410091,
        0.000014126422746690786,
        0.000014260720148627437,
        0.00001977795309614586,
        0.00002507729147210432,
        0.000022451594693663755,
        0.00001895826132306993,
        0.00001740431060786938,
        0.00009646184051334242
      ],
      "range": 1
    }
  }
]
