    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2710389 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2710389; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014614448331955302,
        0.025735680376506836,
        0.02570081268777286,
        0.001233029207246635,
        0.0005659124944795747,
        0.006436874190383741,
        0.028365544576811664,
        0.05216041313626937,
        0.08651890558882876,
        0.08199236345779147,
        0.06736195431725851,
        0.05054445690268075,
        0.03433683873421859,
        0.000061019624858276795,
        0.00006709770811496061,
        0.00011028863384554762,
        0.010574057081843233,
        0.26856266757280967,
        0.6086849526027444,
        0.7619711414118047,
        0.7360430919694553,
        0.6633408709967461,
        0.5710958832846502,
        0.4944024640005548,
        0.41800405772012794,
        0.3378528690900088,
        0.2631760053630678,
        0.17789281907504786,
        0.10002291184032992,
        0.03972862198009215,
        0.027262113667078782
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2710389 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2710389; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017326199302019007,
        0.029511129214293594,
        0.05741874321361251,
        0.09065443742577171,
        0.12778610007640967,
        0.15570396721651392,
        0.19637718423444014,
        0.2774432378525739,
        0.3854242177045435,
        0.5010397400520736,
        0.6449026320576123,
        0.8207375029931128,
        0.9500372086811154,
        1,
        0.9894632098934875,
        0.9290112231122543,
        0.8362944949968435,
        0.7074499638243809,
        0.5710427912746104,
        0.4298836956613976,
        0.3090207346620724,
        0.21398670080198817,
        0.16360727925032162,
        0.12608101641498692,
        0.09416838689944505,
        0.06476243815924576,
        0.05297192764581024,
        0.03198142406864845,
        0.01748547717689232,
        0.013349548717914661,
        0.005116373701339549
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC R1 / prf-solomatov-pred-sony-dsc-r1-dc220445bf14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2710389 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2710389; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04528224177415123,
        0.11298029913787283,
        0.26830940503374234,
        0.45696529169798134,
        0.5837289776485958,
        0.6693770894141025,
        0.7315187967483634,
        0.7335287296399151,
        0.6760589716088723,
        0.5648661871045079,
        0.4205086428553244,
        0.28376679509841574,
        0.17596038797382957,
        0.11195488544264309,
        0.09744978672803054,
        0.09678675275025096,
        0.11057552993315718,
        0.10773918799109647,
        0.08337411345751476,
        0.061655688537696984,
        0.05104803775399029,
        0.0384630434967084,
        0.016169247292547304,
        0.0000031044141634282015,
        0.00002050650441689366,
        0.000023040855021179617,
        0.000027301664078477292,
        0.000007266782000664849,
        0.000023886183865120467,
        0.000031802043913253775,
        0.00015287394171094995
      ],
      "range": 1
    }
  }
]