[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27842212 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27842212; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009400615870606832,
        0.019620682437156933,
        0.024597874263725887,
        0.0040722403809007705,
        0.017817740199665172,
        0.03146775838069188,
        0.04191896821991012,
        0.04864021579894586,
        0.059366784506920636,
        0.04873365305888771,
        0.03463662298096142,
        0.025579688136847748,
        0.02992899414744777,
        0.032204837029471654,
        0.032930729426239556,
        0.0493040423655994,
        0.10051681238545271,
        0.2460498109848456,
        0.4517977594596292,
        0.5766349670780468,
        0.5642640749951908,
        0.5137483329269958,
        0.4403230605384371,
        0.374739226897633,
        0.3085907326616147,
        0.24129381314961615,
        0.1837982987845937,
        0.1231899247085684,
        0.0702804683765787,
        0.029577851070166406,
        0.015285801645357774
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27842212 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27842212; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01578093866967179,
        0.02728040537871057,
        0.05566787222222142,
        0.0934695813680321,
        0.13152164059378615,
        0.15637516875455154,
        0.19711618459050595,
        0.2801532076546217,
        0.38309971923207825,
        0.4991031603379789,
        0.6468361062691427,
        0.8247498438701637,
        0.9512644325817216,
        1,
        0.9836493953856829,
        0.917967796524213,
        0.8168072278165256,
        0.6740035238579464,
        0.5178422246048554,
        0.3666448772101872,
        0.2378279786103202,
        0.14558800141310613,
        0.09609380174247649,
        0.06653347801532436,
        0.04631133833762921,
        0.03033850004446486,
        0.028014571543381682,
        0.014746943597728513,
        0.003571876042032867,
        0.0065130776965565814,
        0.0013438379105798059
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX10M4 / prf-solomatov-pred-sony-dsc-rx10m4-e1f69f7981cd@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27842212 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27842212; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04742042765854954,
        0.11828550834969577,
        0.2739358137205478,
        0.45048001214846006,
        0.5861062332260095,
        0.6962848354146575,
        0.7859030740804646,
        0.830285718677812,
        0.822882463505414,
        0.7194953475679303,
        0.5598464303051784,
        0.37788443317650194,
        0.2117361580322713,
        0.09275186181327834,
        0.04873183208288192,
        0.028547006250796456,
        0.039258263675314306,
        0.04848677253086069,
        0.04133778594890377,
        0.02988951811731051,
        0.03542133433938367,
        0.03427184233781425,
        0.026373933220535783,
        0.003949044350355496,
        0.000011118929056355149,
        0.000024695552206843335,
        0.00043040037551614075,
        0.000020550384430662333,
        0.000177678397104368,
        0.00036863373499203294,
        0.001419954851288396
      ],
      "range": 1
    }
  }
]
