[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28088403 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28088403; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007666184510383163,
        0.01719330821335766,
        0.024877595568534104,
        0.011576642502601518,
        0.03415289933001887,
        0.05054467852800318,
        0.06069937831638203,
        0.0626029397256939,
        0.06773566300654402,
        0.05896036880416448,
        0.0431458420758204,
        0.03301152436469955,
        0.03372347655365098,
        0.032291896410059334,
        0.02885241642253566,
        0.03897168165808501,
        0.08293869537545441,
        0.2215272616246641,
        0.4313506894642604,
        0.5669949622981413,
        0.5633401087274346,
        0.5195337378205518,
        0.44733369141705925,
        0.38813217682756834,
        0.3277723194159526,
        0.26875714507514004,
        0.21305361504532672,
        0.1473699661742962,
        0.09207002619550851,
        0.0356681154140376,
        0.022773939835596918
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28088403 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28088403; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01526888374536637,
        0.023930541725707938,
        0.05141666473526458,
        0.08922574202598844,
        0.12215276176434808,
        0.14468999892945142,
        0.18936164864908836,
        0.28089142697076797,
        0.38906843511181466,
        0.5089007730343373,
        0.6628525302773532,
        0.8422714883434277,
        0.9609637472091239,
        1,
        0.9734108770797685,
        0.9036086530088592,
        0.7970452431916475,
        0.6413408053138514,
        0.4633668208192541,
        0.30787396492424296,
        0.19199643710608966,
        0.11116328685543282,
        0.07078345109189725,
        0.03872006179917028,
        0.013225493809669421,
        0.00004870433181979054,
        0.00006324928120690949,
        0.0000249297929113307,
        0.000022541380512092484,
        0.000019752657351149513,
        0.00016239855288319524
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC RX1RM2 / prf-solomatov-pred-sony-dsc-rx1rm2-a3a8e8928d91@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28088403 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28088403; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04434557920576687,
        0.11355963170992668,
        0.26993380862557403,
        0.4496113217971132,
        0.5891081810525147,
        0.6960094171249251,
        0.7833384831455174,
        0.822363663751193,
        0.8111345810582395,
        0.7064104712539193,
        0.5460145242148512,
        0.3722920096240431,
        0.2152363165680868,
        0.09923682738388508,
        0.048959397940851246,
        0.01662679789947474,
        0.010716388183407935,
        0.02217782192885797,
        0.038135842041286575,
        0.03453600761851786,
        0.017165874471396614,
        0.00338161019692006,
        0.00003382834901649624,
        0.0006516034749287811,
        0.004671823456819528,
        0.00988217379250789,
        0.011351792410554633,
        0.00914195904979005,
        0.006894979041706288,
        0.0005205743452199828,
        0.0015935991804162024
      ],
      "range": 1
    }
  }
]
