[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00053073690566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28129056; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010914799664802115,
        0.02382223909543838,
        0.029995520552874307,
        0.003041217556447268,
        0.019260784358287097,
        0.03490444621469779,
        0.0492200433014114,
        0.059575895813015124,
        0.0767874573359305,
        0.06675622030059143,
        0.05353382004714271,
        0.0448035103965514,
        0.05070158422390986,
        0.04827484079096007,
        0.04332279734494441,
        0.05601138487612886,
        0.09665753574219788,
        0.2384572965805467,
        0.44107508840925785,
        0.539684231354998,
        0.5103850208600436,
        0.4548743838539567,
        0.38205145391069945,
        0.3136825029064676,
        0.2516534648816512,
        0.1929162418116971,
        0.1423872351820556,
        0.091936852471757,
        0.049585748577179824,
        0.020532199882209168,
        0.009423417200451274
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00053073690566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28129056; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021181447681713882,
        0.034187189963844136,
        0.06554348726845023,
        0.10515728771288026,
        0.1442525804504909,
        0.16838210994354022,
        0.2126518703494784,
        0.30659671440577924,
        0.41764187862069263,
        0.533810011039032,
        0.681422897377004,
        0.8540822685547752,
        0.967223109086917,
        1,
        0.9650737565007776,
        0.8869281635977466,
        0.7721869400299616,
        0.6246040174958204,
        0.4666045242721067,
        0.3189518194222553,
        0.1978743118859019,
        0.11391585649221135,
        0.07104323086259413,
        0.04732252916755802,
        0.03175361548304358,
        0.02007651835990405,
        0.01946662166370215,
        0.009930763491958624,
        0.0002330328335582964,
        0.004352742366047262,
        0.0007043841367648962
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCA 77M2 / prf-solomatov-pred-sony-ilca-77m2-36e69e355ef7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00053073690566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28129056; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05919838467028541,
        0.14524798910820877,
        0.33526592573885167,
        0.5508844736667424,
        0.6995844245375833,
        0.80104389014848,
        0.8772773728285118,
        0.897930292011403,
        0.8633485099298509,
        0.7396755301053566,
        0.5639344406012061,
        0.37835046841690984,
        0.2156473001002675,
        0.10294220325061744,
        0.06073530627837214,
        0.03744851522277114,
        0.04356507117713848,
        0.04831444284589759,
        0.04542702423503617,
        0.036470711450315385,
        0.03532375419921664,
        0.027711010070809363,
        0.014322794826173173,
        0.0007303258933531559,
        0.00009078185582374325,
        0.000013863713898375566,
        0.000011901915698195423,
        0.000001400413625099331,
        0.00003857935085301957,
        0.000034149680300868164,
        0.00013575129345664089
      ],
      "range": 1
    }
  }
]
