[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2761489 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2761489; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007881413252053512,
        0.01583180812959965,
        0.02685268816931735,
        0.017314595133277738,
        0.041886185315241166,
        0.05438944714246553,
        0.06116071438271165,
        0.06032148598093276,
        0.06344414191039689,
        0.05440772713561416,
        0.040891957201350436,
        0.028555808116563206,
        0.024658070338140044,
        0.018418473874058525,
        0.008994212180457718,
        0.013129920850671505,
        0.05236153031933135,
        0.19917004920171694,
        0.42283065404207665,
        0.5721836299184969,
        0.5711839518462685,
        0.5274203880587611,
        0.4661652825703814,
        0.41437213764023684,
        0.35659225874157024,
        0.30590826181092884,
        0.24704793681959264,
        0.17473402935879884,
        0.10490511097455034,
        0.046864177260890774,
        0.032153153606623096
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2761489 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2761489; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016317240445281513,
        0.02705312134142124,
        0.05361266693439663,
        0.09736073545829806,
        0.1359854955062287,
        0.1575036366250237,
        0.196545939527552,
        0.2797617879339733,
        0.3798623315175255,
        0.5019322908764077,
        0.6555109218251458,
        0.8353914500474202,
        0.9563451818928123,
        1,
        0.9790190002567456,
        0.915202993747214,
        0.8145275972491652,
        0.6708739017247579,
        0.5125615564646465,
        0.37338160680705235,
        0.2663129203121939,
        0.18926949917236682,
        0.1406329483840059,
        0.09814899498060649,
        0.06052181993120379,
        0.03184982811809137,
        0.01664850376010913,
        0.0025938830464289375,
        0.0003009484738124976,
        0.0024046168570651563,
        0.00016053254240737516
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM3A / prf-solomatov-pred-sony-ilce-7rm3a-ffd0ea6abcbe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2761489 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2761489; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04672278252783191,
        0.11370059051475491,
        0.27304320241724667,
        0.45884557208085935,
        0.6002841220805153,
        0.713466647884529,
        0.8052277593718462,
        0.8432081750099313,
        0.8263191705634171,
        0.7022841662595796,
        0.5308737423904278,
        0.34920233250974386,
        0.1913655060729918,
        0.0773904802807471,
        0.03223584812396501,
        0.002471180837584361,
        0.0022168581877385716,
        0.01860619035599997,
        0.034913588285160654,
        0.03340658970577105,
        0.01846597433486065,
        0.004820910023541648,
        0.0021969321623225733,
        0.004057385707493312,
        0.008028523379959145,
        0.010736259677297286,
        0.01110372701104368,
        0.008634565627456783,
        0.004182847369661803,
        0.001706917898278791,
        0.0021147708355890612
      ],
      "range": 1
    }
  }
]
