[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27735832 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27735832; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009542831814095211,
        0.020643744885677127,
        0.025311903389088886,
        0.0021883520566464347,
        0.02033247100717945,
        0.03677332809053646,
        0.052756848974279916,
        0.06446903413605909,
        0.084601154203703,
        0.07870994098897051,
        0.06732393677608085,
        0.06017164006473647,
        0.05843251790680014,
        0.04350423308015422,
        0.026206834177536123,
        0.028341403279339157,
        0.07332800761123734,
        0.2670533193307488,
        0.5316493840891451,
        0.649431969446599,
        0.6181921998950671,
        0.558679977582789,
        0.4763551711735203,
        0.4035602753867272,
        0.3333168083798604,
        0.26563084532672393,
        0.20245091620110767,
        0.13285622728029214,
        0.07711243708138989,
        0.03220830548728446,
        0.021565724078513312
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27735832 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27735832; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01712828373059081,
        0.027880406111487843,
        0.055157728818086296,
        0.08947943223769167,
        0.12513489409656073,
        0.15434182756803544,
        0.20378210756396276,
        0.296784913465008,
        0.40948376814512,
        0.5284039433177992,
        0.6763834234357924,
        0.8473234911431538,
        0.9626605035680921,
        1,
        0.9779849762574276,
        0.9130667866750852,
        0.8102203676457227,
        0.6615918714823481,
        0.49825979620874544,
        0.3515644311661536,
        0.23438688985425063,
        0.14764751603629558,
        0.10068812430072406,
        0.06597358247627112,
        0.040850990155983063,
        0.022203148620167586,
        0.01587566581741626,
        0.005876337872251317,
        0.00008085197876883593,
        0.005295902426867887,
        0.00004805193152309259
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony ILCE 7RM4A / prf-solomatov-pred-sony-ilce-7rm4a-3af54e7e84e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27735832 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27735832; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045647860860997425,
        0.11175934437445395,
        0.26441680206312185,
        0.44516629246961115,
        0.5777595566630199,
        0.672943432884941,
        0.7509614278021298,
        0.7781521390813155,
        0.7602512158279586,
        0.6679380665415049,
        0.525268612818249,
        0.3725784393271491,
        0.22996934074305037,
        0.12852748386996288,
        0.08196580870550413,
        0.05109476254399003,
        0.04383401586799344,
        0.05025124539260261,
        0.05881984358716912,
        0.050267188667713306,
        0.028473171455610204,
        0.013375958940045498,
        0.0026795096682154696,
        0.00307277712094593,
        0.004320770330596176,
        0.006398440832782662,
        0.005935586861068383,
        0.0055135558940507,
        0.00882147216640193,
        0.0010821397750029637,
        0.000985239454868345
      ],
      "range": 1
    }
  }
]
