[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27500147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27500147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011599094361204687,
        0.0227349017443434,
        0.03206420678405828,
        0.006856370622309764,
        0.020616017070745108,
        0.04417535658991204,
        0.0614840349762494,
        0.07020545017450269,
        0.07944681168431572,
        0.04152238531670394,
        0.007555614157262504,
        0.000006114545133158742,
        0.00023585483015781694,
        0.0000060115820471796014,
        0.022951222769827376,
        0.05672285679054733,
        0.11426184376396241,
        0.23982686347094795,
        0.4190200656018311,
        0.5481801242735175,
        0.5296513142275203,
        0.47445222747354765,
        0.4041151489117494,
        0.3621900275660344,
        0.30053057534565175,
        0.23877812725873793,
        0.18453097723441259,
        0.12257276297468517,
        0.07478713841056922,
        0.03331685826988488,
        0.015707306219126752
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27500147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27500147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01673679053424696,
        0.031229793062560716,
        0.0764039552224939,
        0.1387687491270501,
        0.21592925666906432,
        0.25626248470599083,
        0.2907247732166668,
        0.3507837976284272,
        0.4293814138520786,
        0.5382422137598027,
        0.6784183008185374,
        0.8479427037244563,
        0.9646329526893074,
        1,
        0.9810871192797623,
        0.9152262713359314,
        0.8208693211712649,
        0.684576886079918,
        0.5280097957294555,
        0.37494614119699066,
        0.24937743060064368,
        0.15445931979927233,
        0.10369418025292737,
        0.06651514990083507,
        0.05275787798516131,
        0.04676549001719882,
        0.05022643697140964,
        0.03458366240733186,
        0.021820057907326818,
        0.013796030981216208,
        0.00848363828746079
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony NEX C3 / prf-solomatov-pred-sony-nex-c3-0c15ef7beaa9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27500147 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27500147; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05380563602078199,
        0.13355801334443776,
        0.2972113203613057,
        0.4600121592077307,
        0.5983470197450217,
        0.7319310329504783,
        0.8438900708421667,
        0.8860610817825809,
        0.854847575905685,
        0.6763173302309983,
        0.4803823775923815,
        0.2874085363980054,
        0.13695264974401772,
        0.04861903465461475,
        0.034123675775260404,
        0.03585794286845084,
        0.05734225347959048,
        0.0567494639210474,
        0.029005528588629,
        0.0072647709846787355,
        0.016984874299035564,
        0.022302326965743125,
        0.02235016780092121,
        0.00008070925220872454,
        0.000004131755368434939,
        0.0000058614708495921854,
        0.0000089674466103763,
        0.0005290150630831173,
        0.00024757144025448297,
        0.0005338424190968869,
        0.0011073896441353567
      ],
      "range": 1
    }
  }
]
