[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2650653 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2650653; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01481902534960253,
        0.02475142276261736,
        0.025737626162307927,
        0.000006358192490680599,
        0.000008299772546613984,
        0.009502192855873628,
        0.04148951597964728,
        0.07280152475635249,
        0.11608117320524414,
        0.12097669894927778,
        0.10679620078524046,
        0.09050678455459843,
        0.06434760792906503,
        0.01988384183067342,
        0.000014671463975103493,
        0.000049236116534303055,
        0.00003934357307425755,
        0.2824850706599468,
        0.6469564292270621,
        0.793906029948092,
        0.7540179721751584,
        0.6763564676326927,
        0.5797670234466752,
        0.49799724822524866,
        0.4291490210148216,
        0.35182725162441103,
        0.27532436724082704,
        0.18591141503621939,
        0.10480720788424588,
        0.044117404277361084,
        0.033780875882282596
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2650653 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2650653; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018186928277673462,
        0.031918557427169834,
        0.05915605701689357,
        0.09402490631553809,
        0.1315724276244382,
        0.169021188363773,
        0.22702996582351595,
        0.3298058252060907,
        0.45646927757047034,
        0.576609952340046,
        0.7070396615475507,
        0.8606322291148634,
        0.966815988362113,
        1,
        0.9813970368811006,
        0.9250166657046396,
        0.8379522329026092,
        0.7043540591695706,
        0.5535926052938652,
        0.41481084095126747,
        0.30390121226731676,
        0.21503089993295993,
        0.15972994956337175,
        0.11306489382050385,
        0.0752391429583578,
        0.04427293576337604,
        0.027298161245549683,
        0.012046650391431848,
        0.005662526932042783,
        0.007245663238454826,
        0.002194683574198509
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony SLT A99V / prf-solomatov-pred-sony-slt-a99v-4ecb991af9aa@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2650653 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2650653; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04564335278891654,
        0.11047827837140507,
        0.26033177484944275,
        0.44738543294803207,
        0.5686879044522237,
        0.6457170365189256,
        0.7040388160955056,
        0.7118819400351536,
        0.6728122089160671,
        0.5917321505304541,
        0.47624992784796805,
        0.3686975624497058,
        0.26840816206421586,
        0.19835287380128597,
        0.15837843731337145,
        0.12597215101335407,
        0.10513283330560431,
        0.10352279985347007,
        0.10469612582258032,
        0.07701144963146817,
        0.03976230762759215,
        0.01236373829392229,
        0.0021455379108468744,
        0.0007876154291036962,
        0.005662386212001345,
        0.009867728442764859,
        0.012430011019926034,
        0.010177607932837682,
        0.005913619021426041,
        0.0021055481045614043,
        0.002043063199898289
      ],
      "range": 1
    }
  }
]
