[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500942075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2654993; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014783371396836076,
        0.028025035627074778,
        0.022674552482453862,
        0.00009820550089655997,
        0.000004356563395150879,
        0.000036000955432525306,
        0.03491688957044495,
        0.07671569434998951,
        0.1282320747487219,
        0.13795602920110703,
        0.12062472481095055,
        0.09335918348087961,
        0.0656033817878529,
        0.015328717250855276,
        0.000032848016785592144,
        0.000008416028749673473,
        0.0000492663176782118,
        0.1946649901961284,
        0.536053855691054,
        0.6896667670999701,
        0.6568274379631133,
        0.58392841367931,
        0.49549618458990413,
        0.4318766284494255,
        0.3807730348771165,
        0.32143268000503783,
        0.26578579520080686,
        0.1948900961489451,
        0.11560760135824884,
        0.04723982492336274,
        0.0353504258902808
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500942075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2654993; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024556559235749398,
        0.036356649803486234,
        0.07048883363570163,
        0.10982721778121625,
        0.15139948597022493,
        0.18646760022845005,
        0.24537229026346902,
        0.35967969214744333,
        0.4925482148163856,
        0.6191016007675088,
        0.7532280446690444,
        0.9005765112500611,
        0.9865741453932272,
        1,
        0.9589085678136197,
        0.8864684505417117,
        0.7905975377605245,
        0.6543075367146209,
        0.5063081769018756,
        0.3759217067615621,
        0.278641943186542,
        0.20316912329483897,
        0.1531815441394214,
        0.10307455388681593,
        0.06276369060812967,
        0.03232753926716133,
        0.01612767665917147,
        0.002749747121069229,
        0.000009771797282460985,
        0.0030123327162679217,
        0.00004023011182542262
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 II Wide angle Camera / prf-solomatov-pred-sony-xperia-1-ii-wide-angle-camera-b50d0788852c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500942075472 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2654993; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.061438290986077934,
        0.14846099901985868,
        0.3411969905113013,
        0.5638849045623113,
        0.6982882740351687,
        0.7724952578866393,
        0.8174900731335752,
        0.8008740536728266,
        0.7338273584902107,
        0.6260180385425053,
        0.4911380218328259,
        0.37316901090311944,
        0.27324577909215986,
        0.19943596838108427,
        0.15439313706218744,
        0.11477815517609821,
        0.08322355853937953,
        0.07502886937270875,
        0.08458964447948346,
        0.061314497959639044,
        0.019743047784557873,
        0.0001049885463870168,
        0.0001051036044284328,
        0.00010291979785149823,
        0.008394449839415771,
        0.01948168556376608,
        0.026369128702490786,
        0.02339210782752099,
        0.014300965117200599,
        0.0057557743827016394,
        0.00520774724668362
      ],
      "range": 1
    }
  }
]
