[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501911509434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2660131; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01596353908886442,
        0.029996712247006427,
        0.025983153058466456,
        0.0008791646578552395,
        0.0002298573102568667,
        0.000007576333755325917,
        0.038121967693876074,
        0.07715412343674612,
        0.12858591362605826,
        0.1310243445199672,
        0.1105675182913924,
        0.0837886000911307,
        0.0554916007172926,
        0.010472522593812107,
        0.0026654664271128833,
        0.004962474547989621,
        0.005710315427806267,
        0.23674257778110872,
        0.5460841376245937,
        0.6856281526698611,
        0.6588893203630447,
        0.5871535958068279,
        0.49646246623726176,
        0.42656064742198846,
        0.3659240965247576,
        0.2973963282259407,
        0.23385774530607245,
        0.16637499005000744,
        0.09191323162833179,
        0.03681927400339045,
        0.02677914994734147
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501911509434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2660131; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023518484888526165,
        0.038297869449323195,
        0.07296770024805975,
        0.11380145581744518,
        0.1566357105413913,
        0.1928408369529337,
        0.2505861089253646,
        0.35573313190774947,
        0.48930010480060315,
        0.6127661182621364,
        0.7445575424668934,
        0.8916302220144973,
        0.9819892979243966,
        1,
        0.9636992410997525,
        0.8912210632415538,
        0.7935514521116226,
        0.6544220619342008,
        0.5052546089932646,
        0.370328464580714,
        0.26639267577423814,
        0.18600532436492664,
        0.13664051428415583,
        0.09143726535534683,
        0.05682221759003597,
        0.029390574663139057,
        0.01562992045857664,
        0.002454718044213477,
        0.0004841610431967448,
        0.0037969407456282024,
        0.00011550653063971017
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 III Telephoto Camera / prf-solomatov-pred-sony-xperia-1-iii-telephoto-camera-23594cbd5963@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501911509434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2660131; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06016792688029273,
        0.14674998666625355,
        0.33971419953879467,
        0.5606542361836647,
        0.6924450422656901,
        0.7717873092214881,
        0.8258663928499238,
        0.8144809049837467,
        0.7520434653092898,
        0.6426538568735057,
        0.5028668106946612,
        0.3739734297767629,
        0.26430710280520303,
        0.18660071252130064,
        0.1455683893011284,
        0.11234972125945539,
        0.09410528016692196,
        0.09158551596723567,
        0.0926488705851782,
        0.06849592860308287,
        0.035219505167226724,
        0.009188448453768063,
        0.0010662450155104538,
        0.000007507266562412341,
        0.0025651408244791326,
        0.007076851524634284,
        0.009103645681701047,
        0.009008438777538152,
        0.004439691973816327,
        0.001733384629161692,
        0.0011061065907763833
      ],
      "range": 1
    }
  }
]
