[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508822018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26967567; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01517361024819184,
        0.027873298565842662,
        0.03389642074937823,
        0.00006900319342343583,
        0.003792838290798452,
        0.01648631265516504,
        0.0455951906486652,
        0.07172354953858368,
        0.10818067279360674,
        0.11052762197718498,
        0.09847397742629137,
        0.08934520936233674,
        0.07853223202694384,
        0.03839769824248512,
        0.00014836270141613966,
        0.00004170969439630272,
        0.000013046573619870333,
        0.22148919419429,
        0.5804264849213003,
        0.7025509109780599,
        0.6287662905098805,
        0.5535572445955994,
        0.4680678765934148,
        0.3945265148399269,
        0.33430450617773566,
        0.2725310216014439,
        0.20681286479713903,
        0.1383878409068861,
        0.07425185626955258,
        0.03287880398240458,
        0.02490126682279389
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508822018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26967567; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022981330045457937,
        0.03744154245112829,
        0.06986487765276041,
        0.10897860071244357,
        0.14390953652518293,
        0.17780580980438054,
        0.2422913928262501,
        0.3554884295848117,
        0.4910734809706786,
        0.615127644224771,
        0.7520112059052269,
        0.8996446746276996,
        0.9876007353574018,
        1,
        0.9622354299120099,
        0.8851348294854267,
        0.7845539434727014,
        0.6435828456001215,
        0.48709082015393557,
        0.35264167194816787,
        0.2505903903628632,
        0.17440904804369597,
        0.1268288400631575,
        0.08649999401603356,
        0.05388384023946246,
        0.0298232679049102,
        0.018324541700799557,
        0.006227221592603741,
        0.004110423185267653,
        0.004577828619096413,
        0.00021014754872028315
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 1 IV Ultrawide Camera / prf-solomatov-pred-sony-xperia-1-iv-ultrawide-camera-a1db8790c69c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508822018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26967567; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.060605351884357984,
        0.14399071027910187,
        0.33227953309353314,
        0.5548781736810516,
        0.6880956686027534,
        0.7653210902480664,
        0.8130513179518326,
        0.8023829379305102,
        0.738097316429522,
        0.6296542745860126,
        0.49396250688836707,
        0.3697583231346446,
        0.2643542392123215,
        0.18928827357692296,
        0.14720840854387682,
        0.11240499833137946,
        0.08539552106106886,
        0.07778776586405806,
        0.08474116845361077,
        0.06077803680476689,
        0.02036825343445579,
        0.00007006691055659684,
        0.00009907380894409799,
        0.000004819360981238321,
        0.0017772263020612872,
        0.009360984286164076,
        0.012987850958489913,
        0.010648378122051619,
        0.006184017780451956,
        0.00289103567484859,
        0.0034955029287058576
      ],
      "range": 1
    }
  }
]
