[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508278603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26938766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015474882656094941,
        0.02775145006687371,
        0.026358555919005346,
        0.0005271776703626878,
        0.000010760654071736417,
        0.009058673660107519,
        0.03932344401082586,
        0.06895252176496022,
        0.10808175954186866,
        0.11646803899553498,
        0.10614655741840588,
        0.09569289484012686,
        0.08169537200090699,
        0.04954280756586995,
        0.008381169387117656,
        0.000011797197533776487,
        0.03770349259077845,
        0.2535476570644985,
        0.5567054434644034,
        0.6833859188625122,
        0.6321013009034391,
        0.5557842887695503,
        0.46758423972927493,
        0.39299063284534635,
        0.328424242896835,
        0.2621305576449253,
        0.19947134189555316,
        0.13156157633215218,
        0.0702860822774663,
        0.027647643817329152,
        0.022122647870571145
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508278603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26938766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022954856673835768,
        0.03874374110565259,
        0.07076295825167063,
        0.10937198899922333,
        0.14743307005970505,
        0.18426059464721667,
        0.2518675591573287,
        0.3656702703757296,
        0.5006998503259826,
        0.6221955264720571,
        0.7563922170748282,
        0.9032529283082159,
        0.9900910871487069,
        1,
        0.9578453119278821,
        0.8758463215832124,
        0.7714071516861611,
        0.6319302971601882,
        0.48166385367568754,
        0.3481486808808402,
        0.24104250914834036,
        0.16195485042012642,
        0.11439512964447808,
        0.07836019619045984,
        0.050272733295856985,
        0.028753031626215945,
        0.01927135114841226,
        0.0081243388592052,
        0.0040305361644343805,
        0.0047928775348065914,
        0.00009525422179429345
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony Xperia 5 II Telephoto Camera / prf-solomatov-pred-sony-xperia-5-ii-telephoto-camera-29cd8093b262@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000508278603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26938766; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05633504890313091,
        0.1357123579327478,
        0.3181432645111828,
        0.5379966499009315,
        0.6791955993151958,
        0.764134816799783,
        0.8183471520106974,
        0.8149550038385638,
        0.7639383147691324,
        0.6667334497710513,
        0.5319733665602946,
        0.40358227509709377,
        0.28548989229299343,
        0.19978106643786134,
        0.14965348944837836,
        0.10839061589464857,
        0.08329860415124966,
        0.07555534430756321,
        0.0792913904739773,
        0.05930884170695036,
        0.02505037245086381,
        0.0020713488375578995,
        0.0009570739156375803,
        0.00037978455840205705,
        0.009368742289457506,
        0.014788770034403782,
        0.01939097744075875,
        0.015154137560407994,
        0.00870741655571096,
        0.0031799868484771315,
        0.0038711114893469354
      ],
      "range": 1
    }
  }
]
