    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502220132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26617667; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017660859618162626,
        0.030410369924606842,
        0.027863990806235146,
        0.00009665371569208718,
        0.00008416389009600278,
        0.008303067299040312,
        0.0489180128403799,
        0.09148598232767573,
        0.14392348338292257,
        0.1371381316945989,
        0.1088769456015811,
        0.07315533959559456,
        0.03876410980519645,
        0.00003075824789603086,
        0.000701843297035261,
        0.00013308494405750752,
        0.00010286167769431377,
        0.19365775752451878,
        0.5290797461700908,
        0.6900356526490088,
        0.6663539789819546,
        0.5933054033525066,
        0.5030695608441978,
        0.4369262811037592,
        0.3769493857805983,
        0.31266773420710503,
        0.25099130201642755,
        0.17611436391240873,
        0.09714080446246916,
        0.0368509373214741,
        0.026326136428753987
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502220132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26617667; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023238893175724227,
        0.037601545061103636,
        0.07615510834536003,
        0.11984693168656183,
        0.16862129509014376,
        0.20210529244855804,
        0.2522028267426913,
        0.3474024032649587,
        0.46561125055588076,
        0.5853241490215609,
        0.72164470687833,
        0.8761692242621723,
        0.9753839223515605,
        1,
        0.9689551019156089,
        0.90150171244603,
        0.8051435215136302,
        0.6649039316104034,
        0.5085639108636458,
        0.37265347268687676,
        0.2764473208715099,
        0.20203309999664976,
        0.15214215830604585,
        0.10302048247975287,
        0.06400612091585638,
        0.030344052085637476,
        0.014038685739107491,
        0.00016806672442320404,
        0.00006349916458294631,
        0.0040397124646356225,
        0.0005725069180555906
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Xiaomi 12S Pro Rear Ultrawide Camera / prf-solomatov-pred-xiaomi-12s-pro-rear-ultrawide-camera-6b4ce7d523a0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502220132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26617667; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06228637703296836,
        0.14617217643729521,
        0.337594894255401,
        0.5604041227798588,
        0.6966887904665998,
        0.7751653057263725,
        0.8310773189132976,
        0.821269135334142,
        0.7551137206164613,
        0.6365406932200945,
        0.4849203654850743,
        0.3471829259042094,
        0.23237937419534177,
        0.15184942391833214,
        0.11440511108655765,
        0.086804086924673,
        0.07444504078276817,
        0.07934353584743073,
        0.08808123398539827,
        0.06967317507132972,
        0.035798538366767205,
        0.009712286358468632,
        0.000033491437557546444,
        0.00020815029737907914,
        0.000012877535963707864,
        0.0019693287371301753,
        0.004388403118830357,
        0.006136336329360698,
        0.002900157534467615,
        0.00014878305090930118,
        0.0010867909326109288
      ],
      "range": 1
    }
  }
]