Xiaomi Redmi Note 9S

camera · Measured / calibrated · relative spectral sensitivity

Documented response scope: camera

Native channel samples

Each channel retains its source wavelength grid and values. The plot uses shared display axes; gaps and negative values remain visible. No normalization, interpolation, averaging, or resampling is applied.

Native response channels for Xiaomi Redmi Note 9SEach channel uses its original wavelength grid. Gaps remain disconnected; values are shown without normalization or interpolation.RGB400 nm700 nm10
Native samples on a shared display axis: 400–700 nm, 0 to 1. Curves are not normalized, averaged, interpolated, or resampled.
  • R
  • G
  • B
Help me choose a file

Profile: Xiaomi Redmi Note 9S · Measured / calibrated
Source: Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras

Download Native CSV

Preserves native wavelength and value samples without interpolation or padding. Response scope: camera. This file does not certify camera calibration. Source terms: unknown. Additional reuse permission is unconfirmed; check the source before reuse.

This research profile type provides native CSV and source JSON only; PixInsight and Siril exports are not generated for this profile.

Why other formats are unavailable
  • Use in PixInsight: This research profile type provides native CSV and source JSON only; PixInsight and Siril exports are not generated for this profile.
  • Use in Siril — source-reviewed: This research profile type provides native CSV and source JSON only; PixInsight and Siril exports are not generated for this profile.
  • Use in Siril — numerical estimate: This research profile type provides native CSV and source JSON only; PixInsight and Siril exports are not generated for this profile.
Source, rights and technical details

Source and rights

Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras

Authors: Shoji Tominaga, Shogo Nishi, Ryo Ohtera

Organization: Kobe Institute of Computing and author affiliations in article

Year: 2021

Accessed:

License status: unknown

Publication is authorized by the project owner. This publication does not grant downstream reuse.

Have license information? Contact the project owner.

Source ID: ohtera-2021

Research details

Configuration
camera_module
as documented by source; details unavailable in TXT
Method
dataset
Ohtera2021
source_category
measured
source_method
OL490 programmable narrow-band source / CS-2000; some SPG-100 monochromator measurements averaged as reported in paper section2.1
Uncertainty
per_channel
{"B":null,"G":null,"R":null}
Provenance
dataset_camera_id
ohtera2021:ohtera-txt-15
profile_prefix
ohtera2021:ohtera-txt-15
source_asset_id
ohtera-txt-15
source_asset_sha256
bbd1b57d07313798a89d9211f2681f2f2add2725b7fb2ff4110889036f0bd4df
source_id
ohtera-2021

Channel metadata

R · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Redmi Note 9S
source_url
https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR
G · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Redmi Note 9S
source_url
https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR
B · 31 native samples
camera_sensor_mapping
not asserted from TXT; paper's attributed claims are separate evidence
citation
{"authors":["Shoji Tominaga","Shogo Nishi","Ryo Ohtera"],"doi":"10.3390/s21154985","organization":"Kobe Institute of Computing and author affiliations in article","title":"Measurement and Estimation of Spectral Sensitivity Functions for Mobile Phone Cameras","year":2021}
grid_evidence
{"section":"2.1","sha256":"0f47e579dad2f65f6df7fd864aefc91b9bbd9a5127314c3c59ac94b74bd3c7d6","url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC8347217/"}
measurement_summary
paper reports OL490 programmable DMD illumination (5-10 nm FWHM) and CS-2000; SPG-100 monochromator (4 nm) sometimes averaged with another system
normalization
unknown; values preserved verbatim
original_source_label
Redmi Note 9S
source_url
https://docs.google.com/uc?export=download&id=1dyVNc8XG8BAACwSrOVZpq73-T8MC4ZXR